Slope data, Or 14 – Metal Sales Image II Installation User Manual

Page 8

Advertising
background image

© Metal Sales Manufacturing Corporation / Subject to change without notice, effective 6/2011

8

This chart should be used when specifying and ordering

panels and flashings. It will help you determine overall

required length of material on sloped applications.

Your building is 28

'

-0

''

wide with a 4:12 pitch

To determine the panel lengths for each side:

(L) X (SLOPE FACTOR) = S

14

'

-0

''

x 1.0541(from chart above) = 14.7573

'

OR 14

'

-9

''

Slope Data

1:12

SLOPE

2:12
3:12
4:12
5:12
6:12

SLOPE

FACTOR

1.0035
1.0138
1.0308
1.0541
1.0833

1.1180

HIP / VALLEY

MULTIPLIER

1.4167
1.4240
1.4362
1.4530
1.4743
1.5000

7:12

SLOPE

8:12
9:12

10:12

11:12

12:12

SLOPE

FACTOR

1.1577
1.2019
1.2500
1.3017
1.3566
1.4142

HIP / VALLEY

MULTIPLIER

1.5298
1.5635
1.6008
1.6415
1.6853
1.7320

EXAMPLE:

L

S

Eave

Peak

L

H

Hip or Valley

Rake

Eave or Gutter

14'-0''

28'-0''

Ridge

14'-0''

28'-0''

4

12

Slope

Advertising