Valley detail – Metal Sales Image II Installation User Manual

Page 25

Advertising
background image

© Metal Sales Manufacturing Corporation / Subject to change without notice, effective 6/2011

25

Valley Detail

Eave flashings must be installed before and Valley flashings. All

Valley flashings must be installed prior to panel installation. If

two or more Valley flashings are required, Valley flashing must be

installed working from eave to peak. It is recommended that ms-HT

underlayment be installed under Valley flashing for added moisture

protection.

1. Install Valley flashing against substrate from the low end to the

high end. To hold Valley flashing in place, fasten to substrate

with #8-18 x

3

/

4

" Truss Head Woodscrews, 4' o.c.

2. Apply a row of Double Bead Tape Sealant across both sides of

Valley flashing approximately 5" from center of valley.

3. Miter cut panel and install first panel so that the panel end

is located the proper distance from the center of the Valley
flashing.

4. Fasten Image II panel with (4) #9-16 x 1" Woodscrews through

Double Bead Tape Sealant, flashing, and into the solid sub-
strate as shown below.

5. If two or more Valley flashings are required, lap the Valley

flashing over the previously Valley installed flashing by a
minimum of 2" placing 2 beads of Tube Sealant between the

Valley flashings.

Image II Panel (4)
Moisture Barrier

#9-16 x 1" Woodscrew (5)
Tube Sealant in flashing laps (6)
Valley (1)

Double Bead Tape Sealant (3)

3"

Min.

Optional Valley

with Offset Cleat

3"

Truss Head Woodscrew, 4' o.c. (2)

(X) Numbers indicate sequence of installation.

Advertising