MAINTENANCE AND TROUBLESHOOTING
“Rodding” cooling channels is performed by inserting a small wire rod through the cooling inlet on top
of the Blade Guard and directing the rod out through each of the cooling flow tubes located on the
underside of the Blade Guard. The cooling channels should be “rodded” until all ports are free of foreign
debris.
NOTE:
(K)
Rod Cooling Channels and
recheck flow
(J)
Clean the Blade Guard Intake
Fitting
4. Blade Stops Turning
(A)
Verify all plugs are fully
installed
(C)
Check power source voltage
is 115V – if not 115v, move to
another circuit
(B)
Verify circuit breaker not
tripped If tripped, reset once
Advertising