MTS FGW900 High-temperature Furnace User Manual
Page 30
Advertising

Operation of Temperature Controller
FGW900 High-temperature Furnace Product Manual
Operation
30
J2 E-STOP pin assignments are as follows:
J4 pin assignments are as follows:
High temperature furnace heating wire N (OUTPUT N): the heating wire of high-
temperature furnace temperature controller N connects the plug-in components.
The socket connects the heating wire on the furnace of N-line side.
J5 pin assignments are as follows:
P
IN
S
IGNAL
1
ESTOPB_OUT-
2
No Contact
3
ESTOP_OUT_MONTION-
4
ESTOP_OUT_MONTION+
5
ESTOP3B+
6
ESTOPA_OUT-
7
ESTOP3B-
8
ESTOP3A+
9
ESTOPB_OUT+
10
No Contact
11
No Contact
12
No Contact
13
ESTOP3A-
14
ESTOP_OUT+
15
No Contact
P
IN
S
IGNAL
1
Upper heating L
2
Middle heating L
3
Lower heating L
4
GND
5
No Contact
6
No Contact
P
IN
S
IGNAL
1
No Contact
2
No Contact
Advertising