40

Beacon 110 Operator’s Manual

Reset Switch
Not Working

•

The buzzer does not
silence when you
press the reset
switch.

•

The alarm 1 or
alarm 2 circuit does
not reset when you
press the reset
switch after the
alarm condition
passes.

•

The reset switch is
disconnected or
misconnected.

•

The reset switch is
malfunctioning.

1.

Verify that the wiring to the ALARM
RESET
(2) terminals of the Alarm/
Controller Terminal Strip is correct and
secure.

2.

If the reset switch difficulties continue,
contact RKI for further instruction.

If Installed,
Option Strobe
Not Working

•

The strobe does not
flash when an alarm
1 or alarm 2
condition occurs.

•

The strobe does not
flash when a fail
condition occurs.

•

The strobe is not
setup to activate in an
alarm 1 or alarm 2
condition.

•

The strobe is not
connected to the
strobe terminal strip
properly.

•

The strobe is
malfunctioning.

1.

Verify that the strobe is setup properly for
the desired alarm operation in
Configuration Mode. See “Chapter 5:
Configuration Mode” on page 26.

2.

Verify that the strobe is wired properly to
the strobe terminal strip. The red wire goes
to the + terminal and the black wire goes
to the - terminal.

Table 9: Troubleshooting the Beacon 110 (Continued)

Condition

Symptom(s)

Probable Causes

Recommended Action