Specifications – RKI Instruments Beacon 110 User Manual
Page 6

2
Beacon 110 Operator’s Manual
Specifications
Table 1 lists specifications for the Beacon 110.
Table 1: Beacon 110 Specifications
Input Power
100/115/220V ~ ±10%, 50/60Hz, 0.2/0.2/0.1A
or
24 V ± 10%, 0.5A VDC
Construction (housing)
Fiberglass/polyester with lexan window (NEMA 4X)
Dimensions
8.5 in. H x 6.5 in. W x 4.5 in. D
(216 mm H x 165 mm W x 108 mm D)
Weight
4.2 lbs.
Safety/Regulatory
C US
186718
Environmental Conditions
•
For indoor or outdoor locations (Type 4X)
•
-20°C to 50°C (-4°F to 122°F) ambient
•
Maximum relative humidity of 80%
•
Main supply voltage fluctuations not exceeding ± 10% of nominal
•
DC supply voltage fluctuations not exceeding ±10% of nominal
•
Overvoltage Category II, Pollution Degree 2
Relays
•
Relay contacts rated for 10A @ 115/220V~ resistive or 10A @ 30V
resistive
•
SPDT Form C
User Controls
•
Three push button control switches
•
One ON/OFF toggle switch
•
One push button reset switch
Signal Output
•
4 to 20 mA, 500 ohms impedance max