Specifications

Table 1 lists specifications for the Beacon 110 Rig Monitor.

WARNING:

When using the Beacon 110 Rig Monitor, you must follow the instructions and
warnings in this manual to assure proper and safe operation of the
Beacon 110 Rig Monitor and to minimize the risk of personal injury. Be sure to
maintain and periodically calibrate the Beacon 110 Rig Monitor as described in
this manual.

Table 1: Beacon 110 Rig Monitor Specifications

Input Power

10.8 - 14.5 VDC, 1A VDC

Construction (housing)

Fiberglass/polyester with lexan window (NEMA 4X)

Dimensions

19 in. H x 7.2 in. W x 5.6 in. D
(483 mm H x 183 mm W x 142 mm D)

Weight

13 lbs.

Environmental Conditions

For indoor or outdoor locations (Type 4X)

-20°C to 50°C (-4°F to 122°F) ambient

Maximum relative humidity of 80%

Relays

Relay contacts rated for 10A @ 115/220V~ resistive or 10A @ 30V
resistive

SPDT Form C except for Alarm 1 relay contact (factory wired to alarm
strobe/horn)

User Controls

Three push button control switches

One ON/OFF toggle switch

One push button reset switch

Signal Output

4 to 20 mA, 500 ohms impedance max

Sampling Method

Diffusion

Detection Range

0 to 100 PPM (parts per million) H

2

S

Response Time

90% in 30 seconds

Accuracy

± 5% of reading or ± 2 ppm H

2

S (whichever is greater)