Replacing the oil mist filter, Push – RKI Instruments Digester Gas Monitor User Manual

Page 92

Advertising
background image

86 • Replacing the Oil Mist Filter

Digester Gas Monitor Operator’s Manual

Replacing the Oil Mist Filter

1.

Turn off the Digester Gas Monitor.

2.

Turn off or unplug power to the Digester Gas Monitor.

3.

Open the housing door of the Digester Gas Monitor.

4.

Turn the regulator knob all the way counterclockwise to close the regulator output.

5.

Locate the oil mist filter. It is located along the middle bottom of the flow assembly.

6.

The oil mist filter must be removed from the flow system with the push fittings attached
because pliers are needed to remove the push fittings from the oil mist filter.

7.

Grasp the gray, straight push fitting on the flow system side. Press the collet toward
the fitting and pull the fitting away from the flow system.

8.

Grasp the white, right angle push fitting on the flow system side. Press the collet
toward the fitting and pull the fitting away from the flow system. The oil mist filter with
fittings still connected can now be removed.

Figure 24: Removing the Oil Mist Filter from the Flow System

Push

FL
O

W

Advertising