Door slab trimming, Trim slab to height, Trim slab to width – Therma-Tru SHOP 3 Door Preparation - U1 Revised User Manual

Page 6

Advertising
background image

Door
Preparation

3.6

2014 (U1 REVISED)

Shop 3

Door Slab Trimming

Trim Slab to Height

- Measure and mark door slab.
- Cut along line with saw, using
carbide-tipped blade. If available,
use panel saw.
- Touch up edges with a rasp or
sandpaper.
- Trimming the bottom rail may
prevent the kerf door bottom from
fitting properly. A replacement
staple-on door bottom may need
to be used.

Trim Slab to Width

- Set planer cutting depth.
- Plane edges of slab.
- Sand smooth if required.
- Paint with primer if required to match
original finish.

C

Hinge

Stile

D

Lock

Stile

A

Top
Rail

B

Bottom

Rail

Maximum height and width trims for doors.

Standard

Doors

a

A

Top Rail

B

Bottom Rail

C

Hinge Stile

D

Lock Stile

Classic-Craft

1-1/4"

1-1/4"

1/32"

b

1/32"

b

Fiber-Classic

1/4"

1/4"

1/32"

1/32"

Smooth-Star

1/4"

1/4"

1/32"

1/32"

Steel Doors

1/4"

1/4"

1/16"

1/16"

b

Inspect corners to verify hardwood thickness before trimming.

Impact

Doors

A

Top Rail

B

Bottom Rail

C

Hinge Stile

D

Lock Stile

Classic-Craft

1"

1"

N/A

N/A

Fiber-Classic

N/A

N/A

N/A

N/A

Smooth-Star

N/A

N/A

N/A

N/A

Steel Doors

c

N/A

N/A

N/A

N/A

Fire Rated

Doors

A

Top Rail

B

Bottom Rail

C

Hinge Stile

D

Lock Stile

Classic-Craft

d

N/A

3/4"

1/32"

1/32"

Fiber-Classic

d

N/A

1/4"

1/32"

1/32"

Smooth-Star

d

N/A

1/4"

1/32"

1/32"

Steel Doors

e

N/A

N/A

1/16"

1/16"

c

Standard steel doors are impact-rated, but cannot be trimmed

when requiring an impact product approval, see re-sizing section.

d

Fiberglass 20-minute positive pressure fire doors can only be

trimmed by Warnock-Hersey or NAMI certified re-machiners.

e

Standard wood-edge steel doors may be fire-rated (if appropriately

labeled), but cannot be trimmed in height when being used as a fire
door, see re-sizing section. 90-minute steel edge fire doors cannot
be trimmed, see 90-minute fire door re-sizing section.

a

Standard doors requiring structural product approval or

certification cannot be trimmed.

Advertising