Door
Preparation

3.60

2014 (U1 REVISED)

Shop 3

5DLQ'HÀHFWRU,QVWDOODWLRQ

Align

Rain
Deflector
Base

Exterior

Sealant

Channel

#8 x 1” stainless steel
phillips pan head screw

Base

Fin

Sealant

Sealant

Exterior

Apply bead of sealant in channel on rain deflector base.

Center rain deflector base on exterior face of panel
and align edge of rain deflector base with bottom
edge of panel.

Attach rain deflector base to panel with #8 x 1”
phillips pan head screws.

Slide rain deflector fin into channel on base.

Apply a 2” long bead of sealant up under the fin
at the center of the door to prevent fin from sliding.

Attach Rain Deflector

Sealant type must be a paintable or stainable elastomeric or polyurethane.

Rain Deflector Cut Down Instructions:

3/0 - No cut down required.
2/10 - Cut 1” off both ends of 3/0 deflector.
2/8 - Cut 2” off both ends of 3/0 deflector.
2/6 - Cut 3” off both ends of 3/0 deflector.
2/4 - Cut 8” off one ends of 3/0 deflector.