Dsi device object, Class code, Services – Rockwell Automation 22-COMM-C ControlNet Adapter User Manual
Page 138: Instances, Class attributes, C-20

C-20
ControlNet Objects
Class Code
Services
Instances
The number of instances depends on the number of components in the
device. The total number of components can be read in Instance 0, Class
Attribute 4.
Class Attributes
DSI Device Object
Hexadecimal
Decimal
0x92
146
Service Code
Implemented for:
Service Name
Class
Instance
0x0E
Yes
Yes
Get_Attribute_Single
0x10
Yes
Yes
Set_Attribute_Single
Instances (Dec.) Single Mode
Multi-Drive Mode
0 – 16383
Instances 0 – 16383 in the drive
Instances 0 – 16383 in Drive 0
16384 – 17407
Instances 0 – 1023 in the adapter
Instances 0 – 1023 in the adapter
17408 – 18431
Instances 0 – 1023 in the adapter
Instances 0 – 1023 in Drive 1
18432 – 19455
Instances 0 – 1023 in the slave
Instances 0 – 1023 in Drive 2
19456 – 20479
Not supported
Instances 0 – 1023 in Drive 3
20480 – 21503
Not supported
Instances 0 – 1023 in Drive 4
21504 – 22527
Not supported
Instances 0 – 1023 in the adapter
Attribute
ID
Access
Rule
Name
Data Type
Description
0
Get
Family Code
BYTE
Code identifying the device.
1
Get
Family Text
STRING[16]
Text identifying the device.
2
Set
Language Code
BYTE
0 = English
1 = French
2 = Spanish
3 = Italian
4 = German
5 = Japanese
6 = Portuguese
7 = Mandarin Chinese
8 = Russian
9 = Dutch