Integral keypad – Rockwell Automation 22B PowerFlex 40 Quick Start FRN 5.xx - 6.xx User Manual

Page 12

Advertising
background image

English-12

Integral Keypad

No. LED

LED State

Description

Run/Direction
Status

Steady Red

Indicates drive is running and commanded motor direction.

Flashing Red

Drive has been commanded to change direction. Indicates
actual motor direction while decelerating to zero.

Alphanumeric
Display

Steady Red

Indicates parameter number, parameter value, or fault code.

Flashing Red

Single digit flashing indicates that digit can be edited.
All digits flashing indicates a fault condition.

Displayed Units

Steady Red

Indicates the units of the parameter value being displayed.

Program Status

Steady Red

Indicates parameter value can be changed.

Fault Status

Flashing Red

Indicates drive is faulted.

Pot Status

Steady Green

Indicates potentiometer on Integral Keypad is active.

(1)

Start Key Status Steady Green

Indicates Start key on Integral Keypad is active.
The Reverse key is also active unless disabled by A095
[Reverse Disable].

No. Key

Name

Description

Escape

Back one step in programming menu.
Cancel a change to a parameter value and exit Program
Mode.

Select

Advance one step in programming menu.
Select a digit when viewing parameter value.

Up Arrow
Down Arrow

Scroll through groups and parameters.
Increase/decrease the value of a flashing digit.
Used to adjust internal frequency of IP66, NEMA/UL Type 4X
rated drives only when a Display Group parameter is shown
and P038 [Speed Reference] is set to internal frequency,
A069 [Internal Freq].

Enter

Advance one step in programming menu.
Save a change to a parameter value.

Potentiometer

(1)

Used to control speed of drive. Default is active.
Controlled by parameter P038 [Speed Reference].

Start

Used to start the drive. Default is active.
Controlled by parameter P036 [Start Source].

Reverse

Used to reverse direction of the drive. Default is active.
Controlled by parameters P036 [Start Source] and A095
[Reverse Disable].

Stop

Used to stop the drive or clear a fault.
This key is always active.
Controlled by parameter P037 [Stop Mode].

(1)

IP66, NEMA/UL Type 4X rated drives are not equipped with a potentiometer.

FAULT

VOLTS

AMPS

HERTZ

RUN

FWD

REV

PROGRAM

Menu

Description

Display Group (View Only)
Consists of commonly viewed drive operating
conditions.

Basic Program Group
Consists of most commonly used
programmable functions.

Advanced Program Group
Consists of remaining programmable functions.

Fault Designator
Consists of list of codes for specific fault
conditions. Displayed only when fault is present.

Advertising