A065 [Analog Out Sel]

0/23

1

0

A066 [Analog Out High]

0/800%

1%

100%

A067 [Accel Time 2]

0.0/600.0 Secs

0.1 Secs

20.0 Secs

A068 [Decel Time 2]

0.1/600.0 Secs

0.1 Secs

20.0 Secs

A069 [Internal Freq]

0.0/400.0 Hz

0.1 Hz

0.0 Hz (for IP66,
NEMA/UL Type
4X drives)

60.0 Hz (for
IP20 drives)

A070
A071
A072
A073
A074
A075
A076
A077

[Preset Freq 0]

(1)

[Preset Freq 1]
[Preset Freq 2]
[Preset Freq 3]
[Preset Freq 4]
[Preset Freq 5]
[Preset Freq 6]
[Preset Freq 7]

0.0/400.0 Hz

0.1 Hz

0.0 Hz
5.0 Hz
10.0 Hz
20.0 Hz
30.0 Hz
40.0 Hz
50.0 Hz
60.0 Hz

(1)

To activate [Preset Freq 0] set P038 [Speed Reference] to option 4.

A078 [Jog Frequency]

0.0/[Maximum Freq]

0.1 Hz

10.0 Hz

A079 [Jog Accel/Decel]

0.1/600.0 Secs

0.1 Secs

10.0 Secs

A080 [DC Brake Time]

0.0/99.9 Secs

0.1 Secs

0.0 Secs

A setting of 99.9 Secs = Continuous

A081 [DC Brake Level]

0.0/(Drive Amps

×

1.8) 0.1 Amps

Amps

×

0.05

A082 [DB Resistor Sel]

0/99

0 = “Disabled”
1 = “Normal RA Res”

2 = “NoProtection”
3-99 = % of Duty Cycle

0

A083 [S Curve %]

0/100%

1%

0% (Disabled)

No.

Parameter

Min/Max

Display/Options

Default

Option

Output Range

Minimum Output Value

Maximum Output Value
[Analog Out High]

DIP Switch Position

0 “OutFreq 0-10”

0-10V

0V = 0 Hz

P035 [Maximum Freq]

0-10V

1 “OutCurr 0-10”

0-10V

0V = 0 Amps

200% Drive Rated FLA

0-10V

2 “OutVolt 0-10”

0-10V

0V = 0 Volts

120% Drive Rated Output Volts

0-10V

3 “OutPowr 0-10”

0-10V

0V = 0 kW

200% Drive Rated Power

0-10V

4 “TstData 0-10”

0-10V

0V = 0000

65535 (Hex FFFF)

0-10V

5 “OutFreq 0-20”

0-20 mA

0 mA = 0 Hz

P035 [Maximum Freq]

0-20 mA

6 “OutCurr 0-20”

0-20 mA

0 mA = 0 Amps

200% Drive Rated FLA

0-20 mA

7 “OutVolt 0-20”

0-20 mA

0 mA = 0 Volts

120% Drive Rated Output Volts

0-20 mA

8 “OutPowr 0-20”

0-20 mA

0 mA = 0 kW

200% Drive Rated Power

0-20 mA

9 “TstData 0-20”

0-20 mA

0 mA = 0000

65535 (Hex FFFF)

0-20 mA

10 “OutFreq 4-20”

4-20 mA

4 mA = 0 Hz

P035 [Maximum Freq]

0-20 mA

11 “OutCurr 4-20”

4-20 mA

4 mA = 0 Amps

200% Drive Rated FLA

0-20 mA

12 “OutVolt 4-20”

4-20 mA

4 mA = 0 Volts

120% Drive Rated Output Volts

0-20 mA

13 “OutPowr 4-20”

4-20 mA

4 mA = 0 kW

200% Drive Rated Power

0-20 mA

14 “TstData 4-20”

4-20 mA

4 mA = 0000

65535 (Hex FFFF)

0-20 mA

15 “OutTorq 0-10”

0-10V

0V = 0 Amps

200% Drive Rated FLA

0-10V

16 “OutTorq 0-20”

0-20 mA

0 mA = 0 Amps

200% Drive Rated FLA

0-20 mA

17 “OutTorq 4-20”

4-20 mA

4 mA = 0 Amps

200% Drive Rated FLA

0-20 mA

18 “Setpnt 0-10”

0-10V

0V = 0%

100.0% Setpoint Setting

0-10V

19 “Setpnt 0-20”

0-20 mA

0 mA = 0%

100.0% Setpoint Setting

0-20 mA

20 “Setpnt 4-20”

4-20 mA

4 mA = 0%

100.0% Setpoint Setting

0-20 mA

21 “MinFreq 0-10”

0-10V

0V = Min. Freq

P035 [Maximum Freq]

0-10V

22 “MinFreq 0-20”

0-20 mA

0 mA = Min. Freq

P035 [Maximum Freq]

0-20 mA

23 “MinFreq 4-20”

4-20 mA

4 mA = Min. Freq

P035 [Maximum Freq]

0-20 mA

Input State

of Digital In 1

(I/O Terminal 05)

Input State

of Digital In 2

(I/O Terminal 06)

Input State

of Digital In 3

(I/O Terminal 07)

Frequency Source

Accel / Decel Parameter Used

(2)

0

0

0

[Preset Freq 0]

[Accel Time 1] / [Decel Time 1]

1

0

0

[Preset Freq 1]

[Accel Time 1] / [Decel Time 1]

0

1

0

[Preset Freq 2]

[Accel Time 2] / [Decel Time 2]

1

1

0

[Preset Freq 3]

[Accel Time 2] / [Decel Time 2]

0

0

1

[Preset Freq 4]

[Accel Time 1] / [Decel Time 1]

1

0

1

[Preset Freq 5]

[Accel Time 1] / [Decel Time 1]

0

1

1

[Preset Freq 6]

[Accel Time 2] / [Decel Time 2]

1

1

1

[Preset Freq 7]

[Accel Time 2] / [Decel Time 2]

(2)

When a Digital Input is set to “Accel 2 & Decel 2”, and the input is active, that input overrides the settings in this table.

See the PowerFlex 40 User Manual for more information on parameters.