English-19 – Rockwell Automation 22B PowerFlex 40 Quick Start FRN 5.xx - 6.xx User Manual

Page 19

Advertising
background image

English-19

A116 [Process Time Hi]

0.00/99.99

0.01

0.00

A117 [Bus Reg Mode]

0/1

0 = “Disabled”

1 = “Enabled”

1

A118 [Current Limit 2]

0.1/(Drive Amps

×

1.8) 0.1 Amps

Amps

×

1.5

A119 [Skip Frequency]

0/400 Hz

1 Hz

0 Hz

A120 [Skip Freq Band]

0.0/30.0 Hz

0.1 Hz

0.0 Hz

A121 [Stall Fault Time]

0/5

0 = “60 Seconds”
1 = “120 Seconds”
2 = “240 Seconds”

3 = “360 Seconds”
4 = “480 Seconds”
5 = “Flt Disabled”

0

A122 [Analog In Loss]

0/6

0 = “Disabled”
1 = “Fault (F29)”
2 = “Stop”
3 = “Zero Ref”

4 = “Min Freq Ref”
5 = “Max Freq Ref”
6 = “Int Freq Ref”

0

A123 [10V Bipolar Enbl]

0/1

0 = “Uni-Polar In”

1 = “Bi-Polar In”

0

A124 [Var PWM Disable]

0/1

0 = “Enabled”

1 = “Disabled”

0

A125 [Torque Perf Mode]

0/1

0 = “V/Hz”

1 = “Sensrls Vect”

1

A126 [Motor NP FLA]

0.1/(Drive Amps

×

2)

0.1 Amps

Rated Amps

A127 [Autotune]

0/2

0 = “Ready/Idle”
1 = “Static Tune”

2 = “Rotate Tune”

0

A128 [IR Voltage Drop]

0.0/230.0 VAC

0.1 VAC

Rated Volts

A129 [Flux Current Ref]

0.00/[Motor NP FLA]

0.01 Amps

Rated Amps

A130 [PID Trim Hi]

0.0/400.0

0.1

60.0

A131 [PID Trim Lo]

0.0/400.0

0.1

0.0

A132 [PID Ref Sel]

0/8

0 = “PID Disabled”
1 = “PID Setpoint”
2 = “0-10V Input”
3 = “4-20mA Input”
4 = “Comm Port”

5 = “Setpnt, Trim”
6 = “0-10V, Trim”
7 = “4-20mA, Trim”
8 = “Comm, Trim”

0

A133 [PID Feedback Sel]

0/2

0 = “0-10V Input”
1 = “4-20mA Input”

2 = “Comm Port”

0

A134 [PID Prop Gain]

0.00/99.99

0.01

0.01

A135 [PID Integ Time]

0.0/999.9 Secs

0.1 Secs

0.1 Secs

A136 [PID Diff Rate]

0.00/99.99 (1/Secs)

0.01 (1/Secs)

0.01 (1/Secs)

A137 [PID Setpoint]

0.0/100.0%

0.1%

0.0%

A138 [PID Deadband]

0.0/10.0%

0.1%

0.0%

A139 [PID Preload]

0.0/400.0 Hz

0.1 Hz

0.0 Hz

A140-
A147

[Stp Logic 0-7]

0001/bAFF

4 Digits
For a list of digit options, refer to the PowerFlex 40
User Manual.

00F1

A150-
A157

[Stp Logic Time 0-7]

0.0/999.9 Secs

0.1 Secs

30.0 Secs

A160 [EM Brk Off Delay]

0.01/10.00 Secs

0.01 Secs

2.00 Secs

A161 [EM Brk On Delay]

0.01/10.00 Secs

0.01 Secs

2.00 Secs

A162 [MOP Reset Sel]

0/1

0 = “Zero MOP Ref”

1 = “Save MOP Ref”

1

A163 [DB Threshold]

0.0/110.0%

0.0%

100.0%

A164 [Comm Write Mode]

0/1

0 = “Save”

1 = “RAM Only”

0

A165 [Anlg Loss Delay]

0.0/20.0 Secs

0.1 Secs

0.0 Secs

A166 [Analog In Filter]

0/14

1

0

A167 [PID Invert Error]

0/1

0 = “Not Inverted”

1 = “Inverted”

0

No.

Parameter

Min/Max

Display/Options

Default

See the PowerFlex 40 User Manual for more information on parameters.

Advertising