Supported bacnet objects, Supported bacnet objects -3 – Rockwell Automation 22-COMM-B PowerFlex BACnet MS/TP Adapter User Manual

Page 41

Advertising
background image

Using BACnet Objects

4-3

The type of drive used on the network determines the specific BACnet
objects that are supported. Refer to

Table 4.A

for descriptions of the

BACnet objects and the drives supporting those objects.

Supported BACnet Objects

Ta

b

le

4.

A

B

A

C

ne

t

Obj

ect

D

escr

ip

ti

ons

an

d S

uppo

rt

ed

Dri

ves

Obje

ct

Name

Use

T

h

is

Obj

ec

t

to

Compat

ib

le P

o

wer

F

le

x

Dr

iv

es

44

M

40

40

0

A

nal

og

In

pu

t (A

I)

O

bje

ct

s

AI0

A

nalog

Input

1 (%)

R

ea

d the

v

alue

o

f Analog

Inpu

t 1 (v

olt

age

or

cur

re

nt)

on th

e

dr

iv

e’

s I/

O

te

rm

inal b

lo

ck.

✔✔✔✔

AI1

A

nalog

Input

2 (%)

R

ea

d the

v

alue

o

f Analog

Inpu

t 2 (v

olt

age

or

cur

re

nt)

on th

e

dr

iv

e’

s I/

O

te

rm

inal b

lo

ck.

✔✔✔✔

An

alog

Out

put

(

A

O)

Ob

je

ct

s

A

O

0

A

nalog

Out

put

1

(%

)

R

ea

d/

wr

ite t

he v

alue of

Ana

lo

g Outp

ut (

P

ow

er

Fle

x 40

) or

An

alog Outp

ut

1

(P

ow

er

fle

x 40

0)

on t

he

dr

iv

e’

s I

/O

te

rm

in

al

bl

oc

k.

T

he d

riv

e m

ust

be

con

figur

ed

to

ac

cept

the v

alue

of t

his o

utp

ut

fr

om t

he ne

tw

or

k.

T

his is do

ne b

y set

ting

the

fo

llow

in

g dr

iv

e p

ara

m

et

er

:

P

ow

erFle

x 40:

A0

65 - [

A

nalog

Out

Sel] t

o the

v

alu

e

“1

8”

(S

etp

nt 0-

10)

, “

19”

(S

et

pnt

0

-20

) or

20

” (Se

tp

nt 4-

20)

P

ow

erFle

x

400:

T

082

- [

A

nalog

Out

1

Sel]

to

th

e v

alu

e “

5”

(Se

tpn

t 0-

10)

,

“12”

(

S

et

pnt

0-

20)

o

r “1

9” (

S

et

pnt

4

-20

)

——

✔✔

A

O

1

A

nalog

Out

put

2

(%

)

R

ea

d/

wr

ite t

he v

alue

o

f Ana

lo

g Out

put

2

on th

e dr

iv

e’

s I

/O

te

rm

inal b

loc

k.

Th

e

dr

iv

e m

us

t be con

figur

ed

to

acc

ept

the v

alue of

this ou

tpu

t fr

om t

he net

w

or

k.

Th

is

is do

ne b

y set

tin

g

dr

iv

e

pa

ra

mete

r T08

5

- [An

alog Out2

Se

l] to t

he v

alue

“5

(S

et

pnt

0

-1

0),

“1

2” (

S

et

pnt

0-

20

) or

19”

(Se

tpn

t 4-

20)

.

——

A

nal

og

V

alu

e (A

V

) O

bje

ct

s

A

V

0

R

ef

er

enc

e

1

(%

)

R

ea

d/

wr

ite t

he Ref

er

ence

1 an

d

R

ef

ere

nce 2 v

alues

. T

he dr

iv

e m

ust

b

e

conf

ig

ure

d

to

ac

cept

it

s sp

eed re

fe

re

nce f

rom t

he net

w

or

k. This is ty

pically

do

ne b

y set

tin

g dr

iv

e

pa

ra

mete

r P03

8

- [Sp

eed Ref

er

enc

e]

to

the

v

alu

e

“5

(Co

m

m P

or

t).

✔✔✔✔

A

V

1

R

ef

er

enc

e 2

(

%

)

✔✔✔✔

A

V

2

O

ut

put

F

requ

ency

(

H

z)

Rea

d

the

driv

e’

s

out

put

fr

equen

cy

.

✔✔✔✔

Advertising