Module installation/removal, Keypad or ready/fault panel removal, Installing the rs1 module – Rockwell Automation 160 RSI SERIAL COMM MODULE User Manual

Page 14: Figure 3.2 removing program keypad module, 3–4 installation and wiring, Program keypad module (or ready/fault panel)

Advertising
background image

3–4

Installation and Wiring

Module Installation/Removal

Keypad or Ready/Fault Panel Removal

Before installing the RS1 Module, it may be necessary to remove a
previously installed Program Keypad Module or Ready/Fault panel.

1. Verify that all power to the drive is removed.

2. Insert a small screwdriver into slot, pry back and pivot module

out. Avoid bending or twisting the contact pins located under the
module.

Figure 3.2
Removing Program Keypad Module

Installing the RS1 Module

After setting the DIP switches, install the RS1 Module in the drive by
following these steps:

1. Verify that all power to the drive is removed.

2. Verify that the latch is up (see Figure 3.3). Insert the module,

ensuring that the pins on the back of the module line up with the
drive connector/expansion port.

3. Press the module down until it is fully seated (sides are flush with

the top surface of the drive).

4. Press the latch down until it snaps into place.

!

ATTENTION: The drive contains high voltage capacitors
which take time to discharge after removal of mains supply.
Before installing or removing a keypad/module, ensure iso-
lation of mains supply from line inputs L1, L2, L3 (R, S,
T). Wait the recommended amount of time for the capacitors
to discharge to safe voltage levels (refer to the 160 User
Manual
for recommended time). Failure to do so may result
in personal injury or death.

1 2 3 4 5 6 7 8 9 10 11

50 | 60

SEL

ESC

T1 U

T3

W

DC

+

DC

T2 V

1 2 3 4 5 6 7 8 9 10 11

SEL

ESC

T1 U

T3

W

DC

+

DC

T2 V

Program Keypad Module
(or Ready/Fault Panel)

Advertising