Reference manuals, Safety precautions – Rockwell Automation 160 RSI SERIAL COMM MODULE User Manual

Page 6

Advertising
background image

p–ii

Preface

Reference Manuals

The following documents contain additional information concerning
Allen-Bradley products. To obtain a copy, contact your local Allen-
Bradley Sales Office or visit the “On-Line Publications” area of the
Allen-Bradley home page on the World Wide Web at: www.ab.com.

Safety Precautions

For

Read This Document

Publication
Number

Information about the DF1 protocol

DF1 Protocol and Command Set Reference Manual 1770-6.5.16

Additional information about networking and the SLC™ 500

SLC 500 Modular Hardware Style Manual

1747-6.2

Information about the AIC+

AIC+ Advanced Interface Converter User Manual

1761-6.4

Instruction set information for the SLC 500 and MicroLogix™
1000

SLC 500 and MicroLogix 1000 Instruction Set
Reference Manual

1747-6.15

For general MicroLogix 1000 information

MicroLogix 1000 User Manual

1761-6.3

For DriveExplorer™ information

DriveExplorer User Manual

9306-5.0

For 160 SSC Drive Information:

160 SSC User Manual Series A
160 SSC User Manual Series B
160 SSC User Manual Series C

0160-5.0
0160-5.9
0160-5.15

A complete listing of current Allen-Bradley documentation,
including ordering instructions. Also indicates whether the
documents are available on CD-ROM or in multi-languages.

Allen-Bradley Publication Index

SD499

A glossary of industrial automation terms and abbreviations

Allen-Bradley Industrial Automation Glossary

AG-7.1

!

ATTENTION: Only personnel familiar with 160 Drives,
Communication Modules and associated machinery should
plan or implement the installation, start-up, configuration
and subsequent maintenance of this module. Failure to com-
ply may result in personal injury and/or equipment damage.

!

ATTENTION: This module contains ESD (Electrostatic
Discharge) sensitive parts and assemblies. Static control
precautions are required when installing, testing, servicing,
or repairing this assembly. Component damage may result
if ESD control procedures are not followed. If you are not
familiar with static control procedures, reference Allen-
Bradley Publication 8000-4.5.2, Guarding Against Electro-
static Damage
or any other applicable ESD protection
handbook.

!

ATTENTION: The drive contains high voltage capacitors
which take time to discharge after removal of AC line power.
Before installing or removing the Communication Module,
ensure isolation of mains supply from line inputs L1, L2,
L3 (R, S, T). Wait the recommended amount of time for the
capacitors to discharge to safe voltage levels (refer to the
160 User Manual for recommended time). Failure to do so
may result in personal injury or death.

!

ATTENTION: When a system is configured for the first
time, the motor must be disconnected from the machine or
process during initial system testing. Hazard of injury or
equipment damage may occur due to unintended or incor-
rect machine motion.

Advertising