background image

Chapter

6

Parameter Descriptions

This chapter provides a listing and description of the RS1 Parameters.

Important: Refer to your 160 User Manual for drive parameter

descriptions.

RS1 Parameters

The RS1 Module contains a set of parameters that are used to define
how the module will interact with the network. These parameters may
be used to set the module’s baud rate, protocol, etc. Parameters may
also be read to attain status from the module.

Parameter Number

Access

[Parameter Name] and Description

Min./Max.
Values

Default

Drive

(N10:, N30:)

RS1

(N13:, N33:)

101

1

Read/Write [Node Address]

Address that the RS1 Module will respond to.
Drive power must be cycled before changes will take affect.

0 to 254

1

102

2

Read Only [DF1 Adapter Ver]

Firmware Version of the RS1 Module.

None

103

3

Read/Write [Fault Mode]

Enables forcing a drive fault for communication errors.

0 = Fault Drive Enabled
1 = Fault Drive Disabled

0 to 1

0

104

4

Read Only [Active Protocol]

The current communication protocol that the RS1 is using.

0 = DF1 Point-to-Point
1 = DF1 Multi-drop
2 = Used by Rockwell Automation Field Service Personnel

0 to 2

0

105

5

Read Only [DIP BAUD Rate]

Selected baud rate from DIP switches SW1-SW2.

0 = 9600 Baud
1 = 2400 Baud
2 = 1200 Baud
3 = EPROM Mode

0 to 3

0

106

6

Read Only [DIP Checksum]

Current checksum switch setting (selected by SW4).

BCC = 0 (OFF)
CRC = 1 (ON)

0 to 1

0

107

7

Read Only [DIP Protocol]

Current protocol selected by SW3.

0 = DF1 Point-to-Point
1 = DF1 Multi-drop

0 to 1

0

108

8

Read/Write [EPROM Protocol]

The communications protocol used when SW1 & SW2 are set to “On”
(EPROM Mode).

0 = DF1 Point-to-Point
1 = DF1 Multi-drop

Drive power must be cycled before changes will take affect.

0 to 1

0

109

9

Read/Write [EPROM Checksum]

The checksum mode used when SW1 & SW2 are set to “On” (EPROM
Mode).

0 = BCC
1 = CRC

Drive power must be cycled before changes will take affect.

0 to 1

0