Quick Start Guide

Allen-Bradley Bulletin 825-P Modular Protection System

26

Figure 16 Main Menu > Targets

Targets

Steps back one level

Row 1

Row 6

49T (Overload Trip)

VARA (VAR Warning)

LOSSTRIP (Undercurrent Trip)

37PA (Underpower Warning)

JAMTRIP (Jam Trip)

27P2T (Undervoltage Warning)

49UBT (Current Imbalance Trip)

59P2T (Overvoltage Warning)

50P1T (Short Circuit Trip)

SPDSAL (Speed Switch Warning)

RTDT (RTD (Widing/Bearing) Trip)

81D1A (Frequency 1 Warning)

PTCTRIP (PTC Trip)

81D2A (Frequency 2 Warning)

50G1T (Ground Fault (Residual) Trip)

OTHALRM (RTD (Other) Warning)

Row 2

Row 7

VART (VAR Trip)

AMBALRM (RTD (Ambient) Warning)

37PT (Underpower Trip)

SALARM (Setting Warning)

27P1T (Undervoltage Trip)

WARNING (General Warning)

59P1T (Overvoltage Trip)

LOADUP (Load Control (Upper))

47T (Phase Reversal Trip)

LOADLOW (Load Control (Lower))

55T (Power Factor Trip)

TIMER1T (Timer 1)

SPDSTR (Speed Switch Trip)

TIMER2T (Timer 2)

50N1T (Ground Fault (Core Balance) Trip)

50P2T (Short Circuit Warning)

Row 31

Row 8

SMTRIP (Start Time Trip)

STOPPED (Stopped State)

81D1T (Frequency 1 Trip)

RUNNING (Running State)

81D2T (Frequency 2 Trip)

STARTING (Starting State)

OTHTRIP (RTD (Other) Trip)

STAR (Star (Wye) Starting State)

AMBTRIP (RTD (Ambient) Trip)

DELTA (Delta Starting State)

PTCFLT (PTC Error Trip)

START (Start Command)

RTDFLT (RTD Error Trip)

Reserved

MCMFLT (MCM Error Trip)

Reserved

Row 4

Row 9

COMMIDLE (Comm Idle Trip)

IN1 (Input 1 State)

COMMLOSS (Comm Loss Trip)

IN2 (Input 2 State)

REMTRIP (Remote Trip)

IN3 (Input 3 State)

COMMFLT (Comm Fault Trip)

IN4 (Input 4 State)

Reserved

IN5 (Input 5 State)

Reserved

Reserved

Reserved

Reserved

Reserved

Reserved

Row 5

Row 10

49A (Overload Warning)

TRIP (Trip Relay State)

LOSSALRM (Undercurrent Warning)

AUX1 (Auxiliary Relay 1 State)

JAMALRM (Jam Warning)

AUX2 (Auxiliary Relay 2 State)

46UBA (Current Imbalance Warning)

AUX3 (Auxiliary Relay 3 State)

RTDA (RTD (Winding/Bearing) Warning)

AUX4 (Auxiliary Relay 4 State)

55A (Power Factor Warning)

AUX5 (Auxiliary Relay 5 State)

50N2T (Ground Fault (Core Balance) Warning)

AUX6 (Auxiliary Relay 6 State)

50G2T (Ground Fault (Core Balance) Warning)

Reserved