Remove pod assembly from enclosure – Rockwell Automation 21G 750-Series POD Remote Mounting Kit User Manual
Page 7
Advertising

Rockwell Automation Publication 750-IN015B-EN-P - September 2011
PowerFlex 750-Series Control Pod Remote Mounting Kit
7
Remove Pod Assembly
From Enclosure
1.
Access the drive enclosure.
2.
Remove the control pod cover.
3.
Disconnect the factory installed internal 24V power supply cable from
P14 located on the fiber interface board.
4.
Disconnect the factory installed inverter fiber-optic cable from the P1
(INV1) fiber-optic transceiver located on the fiber interface board.
T20 or F - 6.4 mm (0.25 in.)
1.8 N•m (16 lb•in)
No.
Name
Description
➊
Internal 24V Power Connection Two point connector to P14.
➋
Inverter Fiber-optic Connection
Fiber-optic cable to P1 fiber-optic transceiver INV1.
➊
➋
P1
INV1
P2
INV2
P3
INV3
P14
P13
Advertising