Original instructions, Reset, Mute dependent override – Rockwell Automation 445L Installation and Operating Instructions User Manual

Page 10: Lockout and restart

Advertising
background image

R

Muting Controller Box Installation and Operating Instructions

10

Original instructions

Reset

The reset function switches on the OSSD safety outputs consider the safety light curtain is uninterrupted.

Figure 16: Reset function

Mute Dependent Override

An error in the muting signal sequence will discontinue the muting condition. If the safety light curtain is then interrupted the OSSD
outputs will switch off. This normally leads to a stoppage of the movement of the material. The muting lamp will flash.

For moving the material out of the protective field area in this situation (protective field interrupted), the start signal triggers the mute
dependant override function.

Figure 17: Mute dependent override function

Lockout and Restart

The following fault conditions will lead to a lockout:

• The connection to the Micro 400 safety light curtain emitter or receiver is interrupted.
• Defect in the electronics of Micro 400 light curtain or the MSR42 controller.
• Supply over- or undervoltage
• Error in EDM

A lockout is indicated with LED “Error Status” (= off ) and with the output signal “Lockout” of connector “PWR/IO” (Pin 4). On the Micro 400
light curtain it is indicated with the red blinking LED (emitter and receiver).

The maximum activation time t(mdo)

a

for

this override function is set to one minute by
default. This time has to be considered on
risk analysis of the application.

The “Reset/Override” switch has to be
mounted at a location, where the dangerous
area can be overseen.

The mute dependant override function is
automatically terminated after the mute
dependant override time t(mdo) has
elapsed, or when the safety light curtain is
no longer interrupted.

a.

Mute dependent override time

24V

Start

0V

24V

OSSD

0V

> 0.1 s

ATTENTION

24V

Start

0V

24V

OSSD

0V

> 0.1 s

24V

OSSD
Light
Curtain

0V

max. t(m do)

Advertising