Muting Controller Box Installation and Operating Instructions

11

R

Original instructions

Figure 18: Power-up function

The lockout mode may be reset by one of two methods:

• Power down, then Power up. If the fault is still present the module will lockout again.
• A start signal on switch “Reset/Override”
• A start signal on connector “PWR I/O” Pin 4

Assuming the cause of the lockout has been eliminated (from activating the “Reset/Override” switch for ten seconds), the controller starts
up. If the safety light curtain is interrupted, e.g. due a pallet, the controller goes into a safe off mode. The “Reset/Override” switch has to
be reactivated again to start the mute-dependent-override function (see Figure 18).

Figure 19: Muting System

24V

Output
Status

0V

24V

Error
Status

0V

24V

Start

0V

24V

OSSD

0V

> 0.1 s

> 10 sec

Muting Controller Box

(MSR42) (445L-AMUTBOX1)

Floor Mounting Plate

(included with

mounting stand)

Muting Sensor

Cantilever

(445L-AMSTDMUT)

Reflector

Light Curtains—POC or PAC—

(GuardShield Micro 400,

Safe 2, OR Safe 4)

Mounting Stand

(445L-AMSTD2M)