Original instructions technical data – Rockwell Automation 445L Installation and Operating Instructions User Manual

Page 25

Advertising
background image

Muting Controller Box Installation and Operating Instructions

25

R

Original instructions

Technical Data

General data

Temperature range

Environment temp.: 0…+55°C (32…131°F); Stock temp.: -25…+70°C (-13…158°F)

Enclosure rating according EN 60529

IP65

Net weight

MSR42
Muting box
Cantilever floor mounting stand

130 g
1.7 kg
5.7 kg

Housing dimensions

111 x 22,5 x 125 mm (incl. plugs)

Certifications

According MSR42

Interfaces

Optical Interface

Weight and packaging

Dispatch packaging

MSR42
Muting box
Cantilever floor mounting stand

280x 200 x 70 mm
300x 200x 200 mm

Dispatch weight

MSR42
Muting box
Cantilever floor mounting stand

350 g
2.3 kg
6.5 kg

OSSD semi conductor outputs (PNP)

Voltage

U

N

- 2 V

Current Max

400 mA short-circuit protected and with cross-fault detection

Leakage current

I

MAX Off

≤ 0.1 mA (C

LOAD

≤ 3.3 uF)

Max. response time t(C) with U

N

protective mode

≤ 17.3 ms

Output S1-S4 (MSR42 GPIO1 – GPIO4)

Nominal voltage

U

N

– 2V (coded) (Short circuit protected)

Current max

100 mA (short-circuit protected)

Leakage current

I

MAX Off

≤ 0.05 mA (C

LOAD

≤ 100 nF)

Status Outputs (PNP), MSR42 Info 1, Info 2

Voltage

U

N

– 2V

Current max

100 mA (short-circuit protected)

Leakage current

I

MAX Off

≤ 0.05 mA (C

LOAD

≤ 4.7 uF)

Inputs (MSR42)

Power supply U

N

+24V DC (EN 60204-1)

at 5% residual ripple

0.85…1.15 U

N

Current consumption

Nominal: 70 mA; Rush-In current: max 1.7 A

Max. power consumption at max. supply voltage

2.1 W (semiconductor outputs unloaded)

Controller protection (external)

5 A slow

Control current into: IN 1, IN 2

2 mA each (min.) (in accordance with EN 61131-2)

Minimum voltage at: IN 1, IN 2

11V DC at activated controller (EN 61131-2)

Start pulse duration

Min.

Max.

50 ms
5s

Mute sensor time delay

> 50 ms

Test pulse duration (min.)

Response time x 2

Control current into: GPIO1 – GPIO4

7 mA

Safety Prevention Lamp
Minimum current at Lamp

8 mA with lamp switched on
0.9 A with lamp switched on

Safety Related Parameter

Probability of a dangerous failure per hour PFH

9.0 E-10 1/h
3.0 E-10 1/h
4.0 E-9 1/h

MSR42 Main M.
MSR45E
GuardShield Micro 400