Muting Controller Box Installation and Operating Instructions

23

R

Original instructions

Adjustment of GuardShield Safe 4, Safe 2, or 440L GuardShield

Adjustment of the safety light curtain GuardShield Safe 4, GuardShield Safe 2, or GuardShield Type 2 or Bulletin 440L GuardShield:

Step 8

Adjustment of the Light Curtain GuardShield Micro 400

Adjustment of the Muting Sensors and Retroreflectors

Use the integrated laser alignment system (ILAS) for easy
verification. Touching the symbol

turns the laser on or off.

The green indicator on the receiver light curtain confirms the
correct allignment.

The Micro 400 light curtain is best aligned by LED indicators. A
green LED indicator on either the emitter or receiver light curtain
confirms the correct alignment.

For the corresponding muting type, check the Muting Types
section on page 12 for sensor positions.

Tighten the cantilever screw when positioned at the correct
height and the muting sensors are at the proper distance to
the light curtain (see the Muting Types section on page 12).

Adjust the reflectors and muting sensors to each other. Check
the status LEDs on the opto-retroreflective sensor for correct
operation.

• A pallet should not interrupt the light
curtain nor the muting sensors. The light
curtain and the muting sensors should be
interrupted by the transported goods only.
• For a correct muting sequence, the
muting sensors must be interrupted from
the goods with a time difference of >50 ms.

Note: The image shows the RightSight with reflector.

Normally, the muting sensor gets mounted on one
mounting bar and the reflectors on the other side.

ATTENTION