5.1.1 Pin assignments of the I/O modules

5.2 System connector assembly

The system plug has holes on the top and rear. Suitable cable glands for
these holes are included with the device.

• One cable gland with M20 cable fitting

• Two blanking plugs for the unused outlets

Note: You can also purchase the SafeZone multizone safety laser scanner
with pre-assembled system connectors (see Section 5.3 “Pre-assembled
system connector” on page 33 and Section 12 “Ordering information” on
page 52).

Figure 51: System connector for SafeZone safety laser scanner

Depending on the application use suitable cable glands on the top or rear.

Use the following cable cross-sections for the individual connections:

Pin

Signal

Function

SafeZone

Singlezone

SafeZone

Multizone

1

+24V DC

Supply voltage SafeZone Multizone

X

X

2

0V DC

Supply voltage SafeZone Multizone

X

X

3

OSSD1

Output signal switching device

X

X

4

OSSD2

Output signal switching device

X

X

5

RESET

Input, reset

X

X

6

EDM

Input, external device monitoring

X

X

7

ERR

Application diagnostic output~error/

X

X

8

RES_REQ

Output, reset required

X

X

9

WF

Output, object in warning field

X

X

10

A1

Static control input A

X

11

A2

Static control input A

X

12

B1

Static control input B

X

13

B2

Static control input B

X

14

Reserved—Do not use

15

Reserved—Do not use

16

+24V DC

Supply voltage output

17

GND

18

Reserved—Do not use

19

Reserved—Do not use

20

+24V DC

Supply voltage output

21

GND

22

Reserved—Do not use

23

Reserved—Do not use

24

25

RxD

RS-422 interface for output of measured
data

26

RxD+

27

TxD+

28

TxD

29

Reserved—Do not use

30

Reserved—Do not use

ATTENTION

The length of the spare cable should be such
that the system plug cannot inadvertently be
plugged into a neighboring SafeZone safety
laser scanner.

From experience 20 to 30 cm spare cable at the
scanner have proven to adequate. In this way
you avoid the inadvertent connection of the
system connector to an adjacent SafeZone
safety laser scanner and operation of a SafeZone
safety laser scanner with an incorrect
configuration. The spare cable enables you to
easily change out the SafeZone safety laser
scanner.

Cable Gland

Cable Diameter [mm

Usage

M20

6…12 (0.24…0.47)

System cables (supply
voltage, outputs, static

M12 (only if supplied)

3…6.5 (0.12…0.26)

Control switch for
restart or reset

RS-422 data cables

Cable

Recommended Cable

Shielded

System cables (supply voltage,
outputs, static input)

9…13 conductors,

0.5…1 mm

2

No

Control switch for restart or reset

2 x 0.25 mm

2

No

RS-422 data cables

4 x 0.25 mm

2

Yes

Cable glands on the

rear

Cable glands on the top