Original instructions – Rockwell Automation 442L SafeZone Singlezone & Multizone Safety Laser Scanner User Manual

Page 48

Advertising
background image

R

SafeZone™ Safety Laser Scanner User Manual

46 10000073050, July 2011

Original instructions

Minimum

Typical

Maximum

Functional Data

Protective safety field of the sensor head with 4.0 m scanning range at 120 ms response time
At 30 mm resolution
At 40 mm resolution
At 50 mm resolution
At 70 mm resolution
At 150 mm resolution

2.80 m
3.80 m
4.00 m
4.00 m
4.00 m

Protective safety field of the sensor head with 4.0 m scanning range at 60 ms response time
At 30 mm resolution
At 40 mm resolution
At 50 mm resolution
At 70 mm resolution
At 150 mm resolution

1.90 m
2.60 m
4.00 m
4.00 m
4.00 m

Protective safety field of the sensor head with 5 m scanning range at 120 ms response time
At 30 mm resolution
At 40 mm resolution
At 50 mm resolution
At 70 mm resolution
At 150 mm resolution

2.80 m
3.80 m
4,80 m
5 m
5 m

Protective safety field of the sensor head with 5 m scanning range at 60 ms response time
At 30 mm resolution
At 40 mm resolution
At 50 mm resolution
At 70 mm resolution
At 150 mm resolution

1.90 m
2.60 m
3.30 m
4,70 m
5 m

Scan angle

190° (-5° to 185°)

Reflectivity

1.8%

Several 1000%
(Reflectors)

Resolution

30, 40, 50, 70, 150 mm

Angular resolution

0.50°

0.25°

Protective safety field supplement generally necessary

100 mm

Supplement for retroreflectors in scan plane at a distance of less than 1 m to the protective safety field boundary
protective safety field boundary

200 mm

Measurement error for measured data error output up to 5.0 m and 1.8% reflectivity
Systematic error
Statistical error at 1

σ

Statistical error at 2

σ

Statistical error at 3

σ

Statistical error at 4

σ

±5 mm
±24 mm
±43 mm
±62 mm
±80 mm

Evenness of the scan field at 5.0 m

±70 mm

Distance from mirror axis of rotation (zero point on the X and Y axis) to the rear of the device
the device

93 mm

Distance between center of the scan plane and the bottom edge of the housing

63 mm

Warning field

Approx. 20



49 m

Distance measuring range

49 m

Number of multiple samplings (configurable via SCD)

2

16

Power up time

9 s

20 s

Restart after (configurable)

2 s

60 s

Advertising