Original instructions, 4 data sheet – Rockwell Automation 442L SafeZone Singlezone & Multizone Safety Laser Scanner User Manual

Page 47

Advertising
background image

SafeZone™ Safety Laser Scanner User Manual

10000073050, July 2011 45

R

Original instructions

11.4 Data sheet

Minimum

Typical

Maximum

General Data

Laser protection class

Laser class I (21 CFR 1040, 10 and 1040.11, DIN EN 60825:2001)

Enclosure rating

IP65 (EN 60529)

Protection class according to DIN VDE 0106, DIN EN 50178

II

Type according to IEC/EN 61496, part 3

3

Functional safety programmable electronic system (IEC/EN 61508)

SIL 2

PFD - probability of failure on demand (minimum requirement = 1E-2)

4.46E-3

Operating temperature range

-10°C

+50°C

Storage temperature range

-25°C

+70°C max.
24 h

Humidity (taking into account the operating temperature range)

IEC/EN 61496-1, section 5.1.2 and 5.4.2, as well as IEC 61496-3, section 5.4.2

Vibration

IEC/EN 61496-1, section 5.1.2 and 5.4.4.1, as well as
IEC 61496-3, section 5.4.4.2

Frequency range

10 Hz

150 Hz

Amplitude

0.35 mm or 5 g

Shock resistance

Single shock

15 g, 11 ms according to EN 60068-2-27

10 g, 16 ms according to IEC/EN 61496-1, section 5.1.2 and 5.4.4.2, as well as IEC 61
496-3, section 5.4.4.2

Sender

Pulsed laser diode

Wavelength

880 nm

905 nm

935 nm

Divergence of the collimated beam

2.5 mrad

Pulse duration

3.1 ns

Average output power

562 μW

Size of light spot at the front screen

12 mm

Size of light spot at 4.0 m scanning range

23 mm

Size of light spot at 5.0 m scanning range

27 mm

Housing

Material

Aluminium die-cast

Color

RAL 1021

Front screen

Material

Polycarbonate

Surface finish

Outside with scratch-resistant coating

System connector

ESD protected

Dimensions SafeZone multizone safety laser scanner)

Œ

Height

185 mm

Width

155 mm

Depth

160 mm

Total weight

3.3 kg

Advertising