Section 13 — Annex

13.1 Manufacturer’s checklist

Checklist for the manufacturer/installer for installing electro-sensitive protective equipment (ESPE)

Details about the points listed below must be present at least during initial commissioning~they are, however, dependent on the respective application,
the specifications of which are to be controlled by the manufacturer/installer.

IMPORTANT

This checklist should be retained and kept with the machine documentation to serve as reference
during recurring tests.

Have the safety rules and regulations been observed in compliance with the directives/ standards applicable to the machine

Yes

Ë

No

Ë

Are the applied directives and standards listed in the declaration of conformity?

Yes

Ë

No

Ë

Does the protective device comply with the required control category?

Yes

Ë

No

Ë

Is the access to the hazardous area/hazardous point only possible through the protective safety field of the ESPE?

Yes

Ë

No

Ë

Have measures been taken to prevent and monitor unauthorized presence in the hazardous area when safeguarding hazardous areas/hazardous points
(mechanical point-of-operation guarding), and have these been secured against removal?

Yes

Ë

No

Ë

Are additional mechanical protective measures fitted and secured against manipulation which prevent reaching below, above or behind the ESPE?

Yes

Ë

No

Ë

Has the maximum stopping and/or run-down time of the machine been measured, specified and documented (at the machine and/or in the machine
documentation)?

Yes

Ë

No

Ë

Has the ESPE been mounted such that the required safety distance from the nearest hazardous point has been achieved?

Yes

Ë

No

Ë

Are the ESPE devices correctly mounted and secured against manipulation after adjustment?

Yes

Ë

No

Ë

Are the required protective measures against electric shock in effect (protection class)?

Yes

Ë

No

Ë

Is the control switch for resetting the protective device (ESPE) or restarting the machine present and correctly installed?

Yes

Ë

No

Ë

Are the outputs of the ESPE (OSSDs) integrated in compliance with the required control category and does the integration comply with the circuit
diagrams?

Yes

Ë

No

Ë

Has the protective function been checked in compliance with the test notes of this documentation?

Yes

Ë

No

Ë

Are the given protective functions effective at every setting of the operating mode selector switch?

Yes

Ë

No

Ë

Are the switching elements activated by the ESPE, e.g. contactors, valves, monitored?

Yes

Ë

No

Ë

Is the ESPE effective over the entire period of the dangerous state?

Yes

Ë

No

Ë

Once initiated, will a dangerous state be stopped when switching the ESPE on or off and when changing the operating mode, or when switching to another
protective device?

Yes

Ë

No

Ë

Has the information label “Important Information” for the daily check been attached so that it is easily visible for the operator?

Yes

Ë

No

Ë

IMPORTANT

This checklist does not replace the initial commissioning, nor the regular inspection by specialist