Specifications
B–3
Heat Dissipation
Altitude Derating
Communications Format
and Configuration
Logic Status Structure
This provides the drive status information that will be sent to the
logic controllers input image table when the communication
module is set to control converter.
Regenerative DC Bus Supply Operation Only — 380-480VAC Input
1336 REGEN
Package
Amp Rating
Converter
Converter
Heatsink
Precharge
Unit
10%
Line
Reactor
Power
Line
Filter
Package
Total
48A
141W
820W
15W
186W
173W
1335W
78A
193W
1110W
29W
258W
236W
1826W
180A
522W
2664W
58W
474W
317W
4035W
Regenerative Brake Operation Only — 380-480VAC Input
1336 REGEN
Package
Amp Rating
Converter
Converter
Heatsink
Precharge
Unit
3%
Line
Reactor
Package
Total
48A
141W
656W
15W
65W
877W
78A
193W
888W
29W
84W
1194W
180A
522W
2131W
58W
168W
2879W
m
(ft)
% of Rated Amps
100%
80%
90%
0
4,000
(13,200)
3,000
(9,900)
2,000
(6,600)
1,000
(3,300)
Altitude
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
Bit 15
Bit 14
Bit 13
Bit 12
Bit 11
Bit 10
Bit 9
Bit 8
Ready
Enabled
Not Used
Faulted
Not Used