Parameters

B-5

44

0x0F-44-1

Stop Select
Stopping mode used by the drive when a stop is initiated.
0 = Coast to stop
1 = Ramp to stop

Get/Set

0 to 1

0

45

0x0F-45-1

Reverse Disable
Disables reverse rotation of the motor.
0 = Reverse enabled
1 = Reverse disabled

Get/
Set

(2)

0 to 1

0

46

0x0F-46-1

IR Compensation
Compensation for the voltage drop across the stator resistance in an induction motor. A
voltage is added to the commanded output voltage based on the load current. The default
value of 100% is the factory determined optimum for the drive. It can be adjusted higher or
lower to suit the needs of the application. A setting of 0% disables this function.

Get/Set

0% to
150%

100%

47

0x0F-47-1

Slip Compensation
Compensation for the inherent slip in an induction motor. A frequency is added to the
commanded output frequency based on load current. The default value of 100% is the factory
determined optimum for the drive. It can be adjusted higher or lower to suit the needs of the
application. A setting of 0% disables this function.

Get/Set

0.0% to
150.0%

100.0%

48

0x0F-48-1

Analog Minimum
The percent of analog input used to represent Parameter 30 - [Minimum Frequency]. If the
minimum analog input equals minimum frequency, no action is needed. If it is desired to
adjust the analog input to equal Parameter 30 - [Minimum Frequency], use Parameter 08 -
[Analog Input] to adjust the analog input to the desired level and then enter the value in
Parameter 48.

Get/
Set

(2)

0.0% to
100.0%

0%

49

0x0F-49-1

Analog Maximum
The percent of analog input used to represent Parameter 31 - [Maximum Frequency]. If the
maximum analog input equals maximum frequency, no action is needed. If it is desired to
adjust the analog input to equal Parameter 31 - [Maximum Frequency], use Parameter 08 -
[Analog Input] to adjust the analog input to the desired level and then enter the value in
Parameter 49.

Get/
Set

(2)

0.0% to
100.0%

100.0%

50

0x0F-50-1

Fault Reset
Resets the drive after a fault. This parameter is a command. It will be reset to 0 = No Action
after the command is completed.
0 = No Action
1 = Reset Fault

Get/
Set

(2)

0 to 1

0

51

0x0F-51-1

Preset Speed 1
Programmed value that sets the frequency that the drive outputs when this preset is selected.

Get/Set

0.0 Hz to
120.0 Hz

10.0 Hz

52

0x0F-52-1

Preset Speed 2
Programmed value that sets the frequency that the drive outputs when this preset is selected.

Get/Set

0.0 Hz to
120.0 Hz

20.0 Hz

53

0x0F-53-1

Preset Speed 3
Programmed value that sets the frequency that the drive outputs when this preset is selected.

Get/Set

0.0 Hz to
120.0 Hz

30.0 Hz

54

0x0F-54-1

Preset Speed 4
Programmed value that sets the frequency that the drive outputs when this preset is selected.

Get/Set

0.0 Hz to
120.0 Hz

40.0 Hz

55

0x0F-55-1

Preset Speed 5
Programmed value that sets the frequency that the drive outputs when this preset is selected.

Get/Set

0.0 Hz to
120.0 Hz

50.0 Hz

56

0x0F-56-1

Preset Speed 6
Programmed value that sets the frequency that the drive outputs when this preset is selected.

Get/Set

0.0 Hz to
120.0 Hz

60.0 Hz

57

0x0F-57-1

Preset Speed 7
Programmed value that sets the frequency that the drive outputs when this preset is selected.

Get/Set

0.0 Hz to
120.0 Hz

70.0 Hz

DeviceNet Parameters
101 0x0F-101-1 Switches MAC ID

The state of the node address DIP switches (1 – 6). This address may not reflect the present
address of the module if the baud rate DIP switches are set to 3. In this case, Parameter 103
- [NV MAC ID] is used.

Get

0 to 63

63

#

Object
Mapping

Name and Description

Access
Rule

(1)

Units/
Range

Factory
Default

(1)

Get = Read. Set = Write. Set access is allowed only if DIP switch 10 on the 1329I Integrated drive/motor is set to On (

Figure 2.3

).

(2)

The parameter can be set only when the drive is stopped.

(3)

The parameter can be set only when the 1329 Integrated drive/motor does not have an active I/O connection.