Class code 0x05 – connection object (continued) – Rockwell Automation 1329I DeviceNet Option FRN 1.XXX User Manual

Page 72

Advertising
background image

C-10

DeviceNet Objects

Class Code 0x05 –
Connection Object
(Continued)

Instance 2 Attributes: Polled I/O Connection (Continued)

Instance 4 Attributes: Change of State/Cyclic I/O Message Connection

Attribute
ID

Access
Rule

Name

Data
Type

Value

14

Get

Produced Connection Path

0x20, 0x04, 0x24, XX, 0x30,
0x03

(1)

(1)

Refer to the DeviceNet specification for a description of the connection path.

15

Get

Consumed Connection Path Length UINT

6

16

Get

Consumed Connection Path

0x20, 0x04, 0x24, XX, 0x30,
0x03

(1)

Attribute
ID

Access
Rule

Name

Data
Type

Value

1

Get

State

USINT

0 = Nonexistent
1 = Configuring
3 = Established
4 = Timed out

2

Get

Instance Type

USINT

1 = I/O Message

3

Get

Transport Class Trigger

USINT

0x00 = Cyclic, ack inhibited
0x03 = Cyclic
0x10 = COS, ack inhibited
0x13 = COS

4

Get

Produced Connection ID

UINT

01101xxxxxx
xxxxxx = Node Address

5

Get

Consumed Connection ID

UINT

Ack inhibited
0xFFFF
Ack enabled
10xxxxxx010
xxxxxx = Node Address

6

Get

Initial Comm. Characteristics

BYTE

0x01 = ack enabled
0x0F = ack inhibited

7

Get

Produced Connection Size

UINT

0 to 4

8

Get

Consumed Connection Size

UINT

0 to 4

9

Get/Set

Expected Packet Rate

UINT

Timer Resolution of 2 msec.

12

Get/Set

Watchdog Timeout Action

USINT

0 = Transition to time out
1 = Auto delete
2 = Auto reset

13

Get

Produced Connection Path Length UINT

6

14

Get

Produced Connection Path

0x20, 0x04, 0x24, XX, 0x30,
0x03

(1)

(1)

Refer to the DeviceNet specification for a description of the connection path.

15

Get

Consumed Connection Path Length UINT

0 =
1 =

ack inhibited
ack enabled

16

Get

Consumed Connection Path

Ack inhibited
Null (no data)
Ack enabled
0x20, 0x2B, 0x24, XX, 0x30,
0x01

(1)

17

Get/Set

Production Inhibit Time

UINT

Timer Resolution of 2 msec.

Advertising