Class code 0x28 – motor data object, C-16 – Rockwell Automation 1329I DeviceNet Option FRN 1.XXX User Manual
Page 78

C-16
DeviceNet Objects
Class Code 0x28 – Motor
Data Object
Class Attributes
Instance 1 Attributes
Common Services
Attribute ID
Access Rule
Name
Data Type
Value
1
Get
Revision
UINT
1
2
Get
Max Instance
UINT
1
6
Get
Max ID Class
UINT
7
7
Get
Max ID Instance
UINT
15
Attribute
ID
Access
Rule
Name
Data Type
Value
1
Get
Number of Attributes
USINT
12
2
Get
Attributes List
Array of USINT
1, 2, 3, 4, 5, 6, 7, 8, 9, 11, 12, 15
3
Get
Motor Type
USINT
7 = Squirrel Cage Induction Motor
4
Get
Catalog Number
SHORT_STRING
(1)
5
Get
Manufacturer
SHORT_STRING “Allen-Bradley”
6
Get
Rated Current
UINT
0.1 Amps
(1)
7
Get
Rated Voltage
UINT
Volts
(1)
8
Get
Rated Power at Rated
Frequency
UDINT
Watts
(1)
9
Get
Rated Electrical
Frequency
UINT
Hz
(1)
11
Get/Set
(2)
Maximum Allowed
Motor Speed
UINT
1500 to 3600 RPM
12
Get
Pole Count
UINT
4
15
Get/Set
Base Speed
UINT
300 to 3600 RPM
(1)
Value varies based on drive model.
(2)
This attribute can be set only when the drive is stopped.
Service Code
Implemented for
Service Name
Class
Instance
0x0E
Yes
Yes
Get_Attribute_Single
0x10
No
Yes
Set_Attribute_Single