Rockwell Automation 1769-BOOLEAN Compact I/O Module Reference Manual User Manual

Page 53

Advertising
background image

Publication 1769-RM016A-EN-P - July 2006

Module Data, Status, and Configuration 53

The following table shows the bits patterns to use to configure the operands.

Bits Patterns Used to Configure the Operands

The default value for each operand is all 0's which corresponds to an operand
selection of None.

Words 9,10,11, 17,18,19, 25,26,27, 33,34,35 Operand

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

0

0

0

0

0

0

None

0

0

0

0

0

1

Real Input 0

0

0

0

0

1

0

Inverted Real Input 0

0

0

0

0

1

1

Real Input 1

0

0

0

1

0

0

Inverted Real Input 1

0

0

0

1

0

1

Real Input 2

0

0

0

1

1

0

Inverted Real Input 2

0

0

0

1

1

1

Real Input 3

0

0

1

0

0

0

Inverted Real Input 3

0

0

1

0

0

1

Real Input 4

0

0

1

0

1

0

Inverted Real Input 4

0

0

1

0

1

1

Real Input 5

0

0

1

1

0

0

Inverted Real Input 5

0

0

1

1

0

1

Real Input 6

0

0

1

1

1

0

Inverted Real Input 6

0

0

1

1

1

1

Real Input 7

0

1

0

0

0

0

Inverted Real Input 7

0

1

0

0

0

1

Virtual Input 0

0

1

0

0

1

0

Inverted Virtual Input 0

0

1

0

0

1

1

Virtual Input 1

0

1

0

1

0

0

Inverted Virtual Input 1

0

1

0

1

0

1

Virtual Input 2

0

1

0

1

1

0

Inverted Virtual Input 2

0

1

0

1

1

1

Virtual Input 3

0

1

1

0

0

0

Inverted Virtual Input 3

0

1

1

0

0

1

Virtual Input 4

0

1

1

0

1

0

Inverted Virtual Input 4

0

1

1

0

1

1

Virtual Input 5

0

1

1

1

0

0

Inverted Virtual Input 5

0

1

1

1

0

1

Virtual Input 6

0

1

1

1

1

0

Inverted Virtual Input 6

0

1

1

1

1

1

Virtual Input 7

1

0

0

0

0

0

Inverted Virtual Input 7