Publication 1769-RM016A-EN-P - July 2006

Module Addressing and Configuration with MicroLogix 1500 73

Input Image

The module's input image file represents input states and output data echo
states. Input word 0 holds the input data that represents the value of inputs
IN0 to IN7. Input word 1 represents the directed state of the module's outputs
OUT0 through OUT3.

For example, to obtain the state of input IN2 of the module when it is in slot
3, use address I:3.0/2.

TIP

The end cap does not use a slot address.

I:3.0/2

Input File Type

Slot

Word

Bit

Bit Delimiter

Word Delimiter

Element Delimiter

0

1

2

3

M

icr

oLog

ix 1

50

0

Compact I/O

Compact I/O

Compact I/O

En

d Cap

Slot Number