Addressing Modes for Your I/O
3–4
Publication 1771-6.5.123 – May 1996
Using Standard-density I/O (8 point) Modules
Standard-density I/O modules provide eight input terminals or eight
output terminals. NO TAG illustrates the 2-slot I/O group concept
with two 8-point input modules. NO TAG shows an 8-point input
module and an 8-point output module in a 2-slot I/O group.
Figure 3.3
Two 8-point Input Modules Using One Word of the Input Image
Table
In p u t
T e rm in a ls
0 0
0 1
0 2
0 3
0 4
0 5
0 6
0 7
In p u t
T e rm in a ls
10
11
12
13
14
15
16
17
1 7 1 6 1 5 1 4
1 2
10 0 7 06 0 5
0 3 0 2 0 1 0 0
0 4
1 1
1 3
O u tp u t im a g e ta b le w o rd co rre sp on ding
to th e I/O gro u p .
u nu se d
1 7 1 6 1 5 1 4
1 2
10 0 7 06 0 5
0 3 0 2 0 1 0 0
0 4
1 1
1 3
In p u t im a g e ta b le w o rd co rre sp on d ing
to th e I/O gro u p .
1 18 67
2-slot I/O Group