The table below offers an explanation of the DRIVE indicator.

If the DRIVE
indicator
displays:

The module status is:

Take this action:

Off

One of the following:

· The axis is not used.

· The axis is a position-

only axis type.

· None, if the axis is not used or is a

position- only type.

· Otherwise, make sure the module is

configured, an axis tag has been
associated with the module, and the
axis type is servo.

Flashing green
light

The axis drive is in the
normal disabled state.

None. The servo axis state can be
changed by executing motion
instructions.

Steady green
light

The axis drive is in the
normal enabled state.

None. The servo axis state can be
changed by executing motion
instructions.