Rockwell Automation 1794-OF8IH FLEX I/0 8 Isolated Output Analog Module User Manual

Page 26

Advertising
background image

26 FLEX I/O Isolated Output HART Analog Module

Publication

1794-IN120C-EN-P - April 2009

Shock, nonoperating

IEC 60068-2-27 (Test Ea, Unpackaged Shock):

25 g

Emissions

CISPR 11:

Group 1, Class A

ESD Immunity

IEC 61000-4-2:

6 kV contact discharges

8 kV air discharges

Radiated RF Immunity

IEC 61000-4-3:

10V/m with 1 kHz sine-wave 80% AM from 80…2000 MHz

10V/m with 200 Hz 50% Pulse 100% AM at 900 MHz

10V/m with 200 Hz 50% Pulse 100% AM at 1890 MHz

3V/m with 1 kHz sine-wave 80% AM from 2000…2700 MHz

EFT/B Immunity

IEC 61000-4-4:

±3 kV at 5 kHz on signal ports

Surge Transient
Immunity

IEC 61000-4-5:

±2 kV line-earth(CM) on shielded ports

Conducted RF Immunity

IEC 61000-4-6:

10V rms with 1 kHz sine-wave 80%AM from 150 kHz…80 MHz

Environmental

Attribute

Value

Advertising