North american hazardous location approval – Rockwell Automation 1794-OF8IH FLEX I/0 8 Isolated Output Analog Module User Manual

Page 5

Advertising
background image

FLEX I/O Isolated Output HART Analog Module 5

Publication

1794-IN120C-EN-P - April 2009

North American Hazardous Location Approval

The following information applies when
operating this equipment in hazardous
locations:

Informations sur l’utilisation de cet
équipement en environnements dangereux:

Products marked "CL I, DIV 2, GP A, B, C, D" are suitable
for use in Class I Division 2 Groups A, B, C, D, Hazardous
Locations and nonhazardous locations only. Each
product is supplied with markings on the rating
nameplate indicating the hazardous location
temperature code. When combining products within a
system, the most adverse temperature code (lowest "T"
number) may be used to help determine the overall
temperature code of the system. Combinations of
equipment in your system are subject to investigation by
the local Authority Having Jurisdiction at the time of
installation.

Les produits marqués “CL I, DIV 2, GP A, B, C, D” ne
conviennent qu’à une utilisation en environnements de
Classe I Division 2 Groupes A, B, C, D dangereux et non
dangereux. Chaque produit est livré avec des marquages sur
sa plaque d’identification qui indiquent le code de
température pour les environnements dangereux. Lorsque
plusieurs produits sont combinés dans un système, le code
de température le plus défavorable (code de température le
plus faible) peut être utilisé pour déterminer le code de
température global du système. Les combinaisons
d’équipements dans le système sont sujettes à inspection
par les autorités locales qualifiées au moment de
l’installation.

WARNING

EXPLOSION HAZARD -

• Do not disconnect equipment

unless power has been removed or
the area is known to be
nonhazardous.

• Do not disconnect connections to

this equipment unless power has
been removed or the area is known
to be nonhazardous. Secure any
external connections that mate to
this equipment by using screws,
sliding latches, threaded
connectors, or other means
provided with this product.

• Substitution of components may

impair suitability for Class I,
Division 2.

• If this product contains batteries,

they must only be changed in an
area known to be nonhazardous.

AVERTISSEMENT

RISQUE
D’EXPLOSION –

• Couper le courant ou s’assurer

que l’environnement est classé
non dangereux avant de
débrancher l'équipement.

• Couper le courant ou s'assurer

que l’environnement est classé
non dangereux avant de
débrancher les connecteurs.
Fixer tous les connecteurs
externes reliés à cet
équipement à l'aide de vis,
loquets coulissants,
connecteurs filetés ou autres
moyens fournis avec ce produit.

• La substitution de composants

peut rendre cet équipement
inadapté à une utilisation en
environnement de Classe 1,
Division 2.

• S’assurer que l’environnement

est classé non dangereux avant
de changer les piles.

Advertising