Publication 2706-6.4

Configuring the DL5 Slave

3-5

DL5 Configuration Options

The following items can be selected or entered from the configuration
menu:

Run Mode

Use the [SpaceBar] to select from the following run modes:

DL Slave Mode

PV Slave Mode

Terminal Mode

Diagnostic Mode

Serial Address

Enter a 3-digit address from 000 to 127 (013 & 018 are invalid). The
address is entered as a decimal value. The serial address only applies to the
DL Slave mode.

Baud Rate

Use the [SpaceBar] to select one of the following baud rates:

9600

1200

300

Cursor Enable

Only available in Terminal and PV Slave modes. Press [Y] or [N] and then
[Enter].

When enabled, the DL5 slave starts up with the cursor visible. When
disabled, the DL5 slave starts with the cursor hidden.

Auto New Line

Only available in Terminal and PV Slave modes. Press [Y] or [N] and then
[Enter].

When enabled, a line feed (LF) occurs after each carriage return (CR). This
allows the DL5 Slave to work with host devices that do not send a CR-LF
combination.