A - specifications, Display characters, Electrical – Rockwell Automation 2706-D11JS_D21JS Dataliner DL5 Slave Displays User Manual
Page 41: Serial communications, Environmental, Mechanical, Specifications, Character set, Appendix

Publication 2706-6.4
Appendix
A
Specifications
Display Characters
Electrical
Serial Communications
Environmental
Mechanical
Character Height
One line display
Two line display
5.31 mm (0.209 inch)
5.94 mm (0.234 inch)
Character Set
Alphanumeric
Upper Case Only
Characters per Display Line
16
Viewing Distance - Approximate
3 meters (10 feet)
Character Type
Vacuum fluorescent, 14 segment characters.
Filtered to blue/green color.
Input Voltage
12-24V DC
Input Current
250 - 125 mA, 300 mA inrush
Electrical Interface
RS-232 (EIA-/TIA-232-E)
Baud Rate
300, 1200, 9600
Data Format
8 data bits, no parity, 1 stop bit
Temperature Range - Operating
0
°
to 50
°
C (+32
°
to 122
°
F)
Temperature Range - Storage
-40
°
to 85
°
C (-40
°
to 185
°
F)
Humidity
5% to 95% (non-condensing)
Enclosure Type
UL listed for NEMA Type 12, 13, 4 (indoor use
only) when panel mounted in a suitable
enclosure of equivalent rating.
Weight - Approximate
Catalog No. 2706-D11JS, -D21JS
1.5 lbs. (0.68 kg)