About Setting a Variable
To set a variable is to write a value to it that can be overĆwritten by

an instruction in the same program, another program referencing

the same variable, or an external device if the variable is mapped to

an input. It is possible for a variable that is set to be overĆwritten on

the next scan of the program. Forced values cannot be set.
The Editor stores and displays up to 64 set variables for the current

editing session. The Editor does not store the list of set variables

after the current editing session has been completed. When you set

a variable, it is added to the bottom of the list. Once the 65th

variable is added to the set list, the variable present at the top of the

set list is removed from the list. Duplicate entries are removed from

the list.
When setting variables that use variable initialization, keep these

points in mind:
D Setting a variable using Retained Value initialization modifies the

variable's retained value, and this value becomes its new initial

value.

D Setting a variable using User Specified Value initialization

changes the variable's current value but not its initial value.

About Forcing a Variable
To force a variable is to write a value to it that cannot be overĆwritten

by an instruction or another program referencing the same variable.

Only unforcing the variable permits its value to be changed. Up to

64 variables can be forced. Forced variables are stored on force

pages, a maximum of four, each containing 16 variables.

About the Set/Force/Unforce Dialog Box
Both setting and forcing operations for ladder programs are

selected from the Set/Force/Unforce dialog box. This dialog box can

be displayed in both a basic and an expanded form and is

associated with only one rack connection at a time. When you

choose the Set/Force/Unforce option from the Online menu, the

basic Set/Force/Unforce dialog box is displayed. This basic dialog

box takes up less room on the screen than the expanded dialog box

so that you can view more of your program. The expanded dialog

box takes up more room, but has more options.
You can switch back and forth between the basic and expanded

dialog boxes using the More button in the basic dialog box and the

Less button in the expanded dialog box.
To set, force, or unforce variables, you must have an online program

window open. The same Set/Force/Unforce dialog box is used for

each online program window using the same rack connection.

Opening a program window using a different rack connection

disables all fields on the Set/Force/Unforce dialog box, except the

force list, that applied to the previous rack connection. Only the

force list is actively updated on the Set/Force/Unforce dialog box for

the online program window(s) using the previous rack connection.

You can unfreeze this dialog by activating the online window that is

used for the other rack connection. If you choose the

Set/Force/Unforce command from the online program window with

the new rack connection, the Set/Force/Unforce dialog box is

updated to reflect the information for the new connection.