Rockwell Automation 5370 CVIM Communications Manual User Manual
Page 172

Appendix C
Numerical Results Data
C–9
Table C.3
Numerical Results Data – Results Block 3
Word #
PI Backplane
RS–232
and
Bit #
Definition
Usage
Notes
Toolset 1
Toolset 2
Remote
I/O
182
446
30
0 – 15
Reference Window
#2 Theta (Integer)
16 . 16 value. Refer to Appendix A. Only if 2 or 3
features are enabled.
183
447
31
0 – 15
Reference Window
#2 (Fraction)
Only if 2 or 3 features are enabled.
184
448
32
0
Reference Window
#2X1/Y1 Pass/Fail
Bit
0 = Pass
1 = Fail
Feature #1.
184
448
32
1
Reference Window
#2X2/Y2 Pass/Fail
Bit
0 = Pass
1 = Fail
Feature #2.
184
448
32
2
Reference Window
#2X3/Y3 Pass/Fail
Bit
0 = Pass
1 = Fail
Feature #3.
184
448
32
3
Combination
Pass/Fail Bit
0 = Pass
1 = Fail
0 if all enabled features pass.
184
448
32
4 – 15
Not Used
185
449
33
0 – 15
Score Reference
Window #2,
Feature #1
186
450
34
0 – 15
Score Reference
Window #2,
Feature #2
187
451
35
0 – 15
Score Reference
Window #2,
Feature #3
188
452
36
0 – 15
Reference Window
#3X1 Position
Feature #1 16 bit integer.
189
453
37
0 – 15
Reference Window
#3Y1 Position
Feature #1 16 bit integer.
190
454
38
0 – 15
Reference Window
#3X2 Position
Feature #2 16 bit integer.
191
455
39
0 – 15
Reference Window
#3Y2 Position
Feature #2 16 bit integer.
192
456
40
0 – 15
Reference Window
#3X3 Position
Feature #3 16 bit integer.
193
457
41
0 – 15
Reference Window
#3Y3 Position
Feature #3 16 bit integer.