Rockwell Automation 5370 CVIM Communications Manual User Manual
Page 176

Appendix C
Numerical Results Data
C–13
Note: Words 2 through 5 select tools for Toolset 1. Words 6 through 9 select
tools for Toolset 2.
Note: Word 0, block signature and word 1 are not used.
Use Table C.5 to set the contents of the programmable results block and
statistics block.
Table C.5
Programmable Results/Statistics Block Configuration
1771 Node Adapter Results or Statistics
RS–232 Results or Statistics
Word #
Toolset 1
Word #
Toolset 2
Bit #
Function
Byte #
Toolset 1
Byte #
Toolset 2
Bit #
2
6
0
Module Status (NA for statistics)
0
8
0
2
6
1
Light Probe
0
8
1
2
6
2
Reference Line 1 (NA for statistics)
0
8
2
2
6
3
Reference Line 2 (NA for statistics)
0
8
3
2
6
4
Reference Line 3 (NA for statistics)
0
8
4
2
6
5
Reference Window 1
0
8
5
2
6
6
Reference Window 2
0
8
6
2
6
7
Reference Window 3
0
8
7
2
6
8
Window 1
1
9
0
2
6
9
Window 2
1
9
1
2
6
10
Window 3
1
9
2
2
6
11
Window 4
1
9
3
2
6
12
Window 5
1
9
4
2
6
13
Window 6
1
9
5
2
6
14
Window 7
1
9
6
2
6
15
Window 8
1
9
7
3
7
0
Window 9
2
10
0
3
7
1
Window 10
2
10
1
3
7
2
Window 11
2
10
2
3
7
3
Window 12
2
10
3
3
7
4
Window 13
2
10
4
3
7
5
Window 14
2
10
5
3
7
6
Window 15
2
10
6
3
7
7
Window 16
2
10
7
3
7
8
Window 17
3
11
0
3
7
9
Window 18
3
11
1
3
7
10
Window 19
3
11
2
3
7
11
Window 20
3
11
3