Use this command to read the results of the last inspection. Refer to
Appendix B for a description of the results blocks. Use the following
commands:
>RRx,TSno,d [CR]
Where:
x
=
Number of times command is repeated.
n
=
Toolset number TS1, TS2, or S
(CVIM module status)
o
=
RL (specifies Reference Line)
RW (specifies Reference Window)
G (specifies Gage)
W (specifies Window)
LP (specifies Light Probe)
d
=
Gage, Window, Reference Line, or
Reference Window number.
>RRx, TS1 [CR]
Reads discrete bit results for toolset 1.
x = Number of times command is repeated.
>RRx,TS2 [CR]
Reads discrete bit first results for toolset 2.
x = Number of times command is repeated.
>RRx,TS1RB,d [CR]
Reads results block(s) for toolset 1
x = Number of times command is repeated.
d = Block number.
>RRx,TS2RB,d [CR]
Reads results block(s) for toolset 2.
x = Number of times command is repeated.
d = Block number.
>RRx, S [CR]
Reads CVIM module status.