Command summary (cont’d) – Rockwell Automation 5370 CVIM Communications Manual User Manual
Page 92

Chapter 5
Using the RS–232 Ports
5–22
Table 5.A
ASCII
Command Summary (Cont’d)
Command
Command Structure
Field Descriptions
Set Configurable Statistics
>SSn,TSxd,TSxd,etc. [CR]
n =
number of samples.
x =
1 or 2
d =
G1, G2, W1, W2,
RW1, LP, etc.
Trigger Inspection
>T,TSn[CR]
n =
1 or 2
Write Display
>W, D, data [CR]
Data = XY
X =
1 (TS1)2
2 (TS2)
Y =
1 to 9
1 = Image only
2 = Failed Tools
3 = All Tools
4 = I/O Page
5 = Results Page
6 = Stats 1 Page
7 = Stats 2 Page
8 = Page Up
9 = Page Down
>W, F, data [CR]
Data = XY
X =
1 (TS1)2
2 (TS2)
Y =
1 to 9
1 = Go On Reject
2 = Freeze On First Reject
3 = Freeze On All Rejects
4 = Freeze On Next Inspection
5 = Halt On Reject
>W, DC, data (CRI
Data = XY
X =
1 (TS1)2
2 (TS2)
Y =
1 to 9
1 = Resume
2 = Reset Statistics
3 = Reset Counters
8 = Page Up
9 = Page Down
Write Configuration Block(W)
>W, CBn [CR] data
n = 1 to 136
Data = ASCII configuration data
Write Configuration Block(WC)
>WC,CBn,CBn,etc. [CR] data
n = 1 to 136
Data = ASCII configuration data
Command Summary (cont’d)