Cvim module configuration instructions – Rockwell Automation 5370 CVIM Communications Manual User Manual

Page 74

Advertising
background image

Chapter 5

Using the RS–232 Ports

5–4

If you are using the RS–232 ports (A or B), you must configure the CVIM
module as follows:

Set the Baud Rate(s)

1 Select the setup menu <Setup>.

1 Select the environment menu <Environ>.

1 Select the I/O menu <I/O>.

1 Select RS–232 communications <RS–232 A> or <RS–232 B).

1 Select the Baud rate which matches your host device; from 300 to 19.2K

Baud.

Note:

When you select RS–232 communications, the data format is fixed as follows:

8 Data Bits

1 Stop Bit

No Parity

Select the CFG and SYS Hosts

Note: The following steps are not necessary if you are just reading results
data.

1 Select the setup menu <Setup>.

1 Select the environment menu <Environ>

1 Select the system menu <System>

1 Select a host menu <CFG Host> or <SYS Host>.

1 Select RS–232 port for host communications <RS–232A> or

<RS–232B>.

Select the Protocol

1 Select the I/O menu <I/O>.

1 Select RS–232 communications <RS–232 A> or <RS–232 B>.

1 Select either <ASCII> or <DF1>.

Select the CVIM module Trigger Source

1 Select the toolset menu <Toolset>

1 Select the trigger source menu for the appropriate toolset <Trigger

Source>.

1 Select either <I/O>, <Hosted>, or <Auto Trigger> trigger source. Select

hosted trigger if you are using the RS–232 trigger commands. Use I/O
trigger if you are using the discrete I/O inputs as a trigger.

Note: The next section of this chapter describes ASCII protocol followed by
a description of DF1 protocol.