2-12 Installation

To connect the touchscreen:

1. For units with the touchscreen option, connect one end of the included

touchscreen serial cable to the touchscreen port connector on the
monitor.

2. Connect the other end to a serial port (usually COM2) on the host

computer.

3. Tighten the captive screws on the cable connector to secure it.

Connecting Power

The RAC6185 Industrial Flat Panel Monitor (6185-F) requires a single-phase
power supply providing 90 to 254V AC at 50 to 60 Hz.

Power must be available at a grounded three-pin outlet located nearby.
Whenever possible, connect the monitor to the same AC source that supplies
the computer.

To connect power to the monitor:

1. Turn off the main switch or breaker.

2. Connect the included power supply cable to the power input connector

on the monitor.

3. Plug the other end of the AC power cord into the main outlet.

4. Restore AC power.

The RAC6185 Industrial Flat Panel Monitor (6185-F) uses a green LED,
located in the upper right corner of the monitor, to indicate when the monitor
is powered up. When you turn the monitor on, the LED will light up.

IMPORTANT

If you need an extra cable restraint, Rockwell Automation
provides a lance in the sheet metal, so you can secure the
power cable to the chassis with a tie wrap.