4Ć2
Analog Rail Module with AutoMate 20
(Local Head Mode or Rail Mode)
AutoMate 20 registers reserved for port configuration:
2734
Port 0 of AutoMate 20
2735
Port 1 of AutoMate 20
2736
Port 2 of AutoMate 20
2737
Port 3 of AutoMate 20
Local Head Mode
Enter the value 64XX for the register representing the port to which the Analog
Rail module is connected, where XX is a value from 00Ć14*. The XX value
represents the first register in a set of four contiguous registers that will be used
to store data for the port.
Rail Mode
Enter the value 16XX for the register representing the port to which the Analog
Rail module is connected, where XX is a value from 00Ć17*. The XX value
represents the register that will be used to multiplex data through the I/O port.
*Values are in octal notation.
Figure 4.1 Ć Configuration for Analog Rail Module with AutoMate 20