8Ć4

Values Returned:
ă1

Success

-2

ENI not initialized

-9

No buffer space

-12 Bad InterNet address

-15 Bad socket number

-102 Socket not connected
For example:

STATUS% = CONNECT%( SN%, DEST_INET_ADDR$, 5001 )

8.5

ACCEPT% Function

Format:

ACCEPT%( sn%, nsn% )

where:

sn%

is the number of the TCP socket that should begin

waiting for a connection to be made. This can be

specified as a simple variable or as an element of

an array.

nsn%

is filled in by this function with a new socket

number created when a connection has been

established. This must be a simple variable; array

elements are not allowed.

This function is used to direct the ENI to do a passive open. This is

valid only on TCP sockets. This function suspends execution of the

task and waits until a connection is established. When a connection

arrives, it creates a new socket with the attributes of the given

socket to service the connection. The application program may then

shut down the original socket sn%, or it may loop back to the

ACCEPT% to wait for another connection to come in. In this way a

given service may have more than one client at a time.

Communication will take place through the new socket.
Values Returned:
ă1

Success

-2

ENI not initialized

-7

Did not accept

-9

No buffer space

-15 Bad socket type

-16 Not a TCP socket
For example:

STATUS% = ACCEPT%( SN%, NSN% )