Rockwell Automation 57C610 Enhanced Basic Language, AutoMax User Manual

Page 135

Advertising
background image

BĆ11

888

BCD output number greater than 9999

889

Bad bit number in function call

890

Bad option number in function call

891

Invalid GATEWAY transfer call

Note: Check returned status variable of

GATEWAY_CMD_OK@ function; decode status error numbers as follows

(01 through 07 are MODBUS exception codes):
Decimal
01

Illegal function code

02

Illegal starting register

03

Illegal data

04

PC aborted

05

Not assigned

06

PC busy

07

Not assigned

08

Illegal data in response message

09

Response timeout error

20

Dual port address error

21

Gateway card not found or not accessible

22

No available Gateway channel

23

Illegal register number

24

Illegal number of register

25

Illegal command number

26

Illegal command number/register set

27

Illegal register number/number of registers

28

Illegal device address

892

BLOCK_MOVE invalid source parameter

893

BLOCK_MOVE invalid destination parameter

894

BLOCK_MOVE invalid transfer size parameter

895

RESUME without executing ON ERROR statement first

956

UDC tick rates do not match

958

PMI gains out of range

959

UDC Processor error

960

Floating point format conversion error

961

Spurious interrupt detected from Multibus

962

CCLK must be enabled to execute task

963

OS background not completing

964

Flash update not completing in time; check utilization

Corrective action: For error code 757, check real and double integer value

ranges.

Error Codes Caused By UDC Modules

1000 SCR fault
1001 MĆcontactor fault
1002 (not used)
1003 Instantaneous overcurrent fault
1004 Synch loss (AC line voltage)
1005 Conduction timeout
1006 Field loss fault
1007 Tach loss fault